ELECTRICITY – Basics


Electricity has been around since the beginning of time in the forms of lightning and static electricity. In 600 BC in Greece, it was observed that amber rubbed with wool would attract light objects such as straw, feathers, and bits of wood. Around 1570, William Gilbert, the man who is credited with coining the word “electricity,” discovered electrical properties in items other than amber. The electric light bulb was invented in 1802, and Thomas Edison was the first person to successfully market an incandescent lamp, in 1879.

With the ever-expanding use of electricity, the need was recognized for a national standard to regulate electrical installations nationwide. The National Electrical Code came into being in 1897.

Through the National Fire Protection Association it became NFPA 70 and remains the same today. It is the electrical standard for the United States and other foreign countries, including Mexico. The code is not a training manual; rather, it is a uniform standard used by inspection agencies, designers, insurance companies, and others who are responsible for electrical installations. The code is a minimum requirement for safe installations, and parts of the code became Subpart S and Subpart K of OSHA’s standards. Electricity Basics:

GROUNDING
When electricity became part of our lives, whether in the workplace or at home, effective grounding became our means of protection. Grounding is still a required method of protection from shock in the event of an electrical fault. This is the separate wire that is run with the circuit conductors and connected to the non-current-carrying metal parts of equipment that could become energized because of a fault.

A grounding conductor is also required in cords that are connected to tools, equipment, and appliances. The only exception is if the tool is supplied through an isolation transformer with an ungrounded secondary of not over 50 volts or uses a system of approved double insulation. The grounding conductor gives a direct path back to the grounding electrode (ground rod, structural steel, etc.) if a fault occurs.

When the transistor was invented, we entered into a new era. Now, we were faced with items such as transistor radios, which operated on batteries or regular household current. In the mid to late 1960s, one could hardly read a newspaper or watch the evening news without reading or hearing about a kid or kids being electrocuted. Typically they would be sitting in the bathtub when their radio (plugged into household current) fell into the tub, and electrocuting them.

Hairstyles were changing during this period, and the hand-held hair dryer became a part of practically every household. They posed a problem because they were primarily used in the bathroom, near the lavatory. This presented additional hazards because the water piping system was grounded, and a fault in the hair dryer along with someone coming in
contact with the faucets could result in serious electrical shock or electrocution.

These factors led to introduction of Ground Fault Circuit Interrupters (GFCIs).

UNDERSTANDING GFCIs
One of the items covered in the National Electrical Code is Ground Fault Circuit Interrupters, or GFCIs. The GFCI is probably the most significant life-saving device ever invented for protection against serious injury or death caused by an electrical shock.

The GFCI is designed for “personal” protection, not for protection of equipment or the conductors of a circuit. While grounding is required and is a vital part of the safety of both people and equipment, the grounding conductor has nothing to do with the operation of GFCIs.

The GFCI senses an imbalance of current between the “hot” and “neutral conductor.” The GFCI really does not care about the current draw (amps) passing through, as long as it is within the designed limits of the device. Rather, it is monitoring the current difference in milliamperes between the hot and neutral. A milliamp is .001 or 1/1000 th of an ampere. If this difference is at 5 milliamperes, plus or minus 1 milliampere, the device “trips out,” breaking the circuit.

A handheld hair dryer that is rated at 1,400 watts, 120 volts, will have a current draw of approximately 11.6 amperes, or 11,600 milliamperes. An industrial 3/8-inch electric drill will have a current draw of between 4 and 6 amperes, or 4,000 to 6,000 milliamps.

While electricity performs many tasks for us and makes our lives more enjoyable, it is basically lazy. The lazy part is that it will seek the path of least resistance to a grounding source. The resistance in a copper wire used as the grounding conductor is very low and will allow current to flow rather freely. In the event of an electrical fault in equipment that has a grounding conductor, the current will flow to ground on the conductor.

EFFECTS OF ELECTRICITY
The adult body has about 500 Ohms of resistance. If a person’s body were to become the path to ground, the body would become a high impedance ground path. There is not enough current flowing through the body to trip an overcurrent device (a fuse or circuit breaker; the GFCI is not an overcurrent device.)

In order for an overcurrent device to trip, the current draw (amps) must exceed the rating of the device. For example, a circuit breaker rated at 20 amperes will not trip open until the current exceeds the 20 amperes. Using Ohm’s Law, on a 120 volt circuit with 500 Ohms of resistance, the current level would be 240 milliamperes, or about 1/4 th of an ampere. Even though this seems like a small about of current, it is quite deadly when passing through the body.

Shock in the range of 6 to 30 milliamps can be very painful, and the person in contact cannot let go of the circuit. At around 50 milliamps respiratory arrest is possible, with severe muscular contractions. Ventricular fibrillation starts around 67 milliamperes of current. This is when the heart basically starts fluttering and is not pumping blood through the system. If not stabilized, death is a real possibility.

So you can see that if the GFCI is functioning properly, the current level will never reach the danger point—because it trips at 5 milliamperes.

TESTING GFCIs
UL 1943 is the standard for testing GFCIs. Each manufacturer must ensure that its product meets this standard. Included in the listing and labeling for GFCIs are instructions that they be tested monthly.

Both the National Electrical Code and OSHA’s electrical standards require that equipment shall be used and installed in accordance with any instruction included in the listing and labeling. The purpose of this is to ensure as much as possible that the device is functioning properly.

The test is a very simple procedure where one can press the test button on the device to ensure that it does trip, breaking the circuit. This test button creates a difference of 5 milliamperes between the hot and neutral through a resister built in the device. There are GFCI testers in the marketplace where you can test the polarity of a receptacle and also trip the GFCI. I have stated that the grounding conductor has no part to play in the operation of the GFCI, but using the external tester the grounding conductor must be present because the tester is using the hot and grounding conductor to trip the device.

ARE YOUR GFCIs WORKING?
We take for granted that our GFCIs are providing protection if we can operate a tool, hair dryer, or other item through them. Yet this is not always the case. While the device will allow current to flow through it, the monitoring of the current may not be taking place.

Built into the device is a metal oxide varistor (MOV) used as a surge suppressor. The MOV absorbs the voltage surge and converts it into heat. Repeated surges can degrade the MOV, still allowing current to flow but not providing the protection required. Voltage surges such as lightning strikes in the area can cause a surge, as can utility company switching. In the event a GFCI trips out, is reset, and power is restored, you should go a step further and press the test button to insure that the device trips open to stop the current flow. If the device will not trip open, or if it trips and current continues to flow, the device is defective and must be replaced.

Some parts of the country are more susceptible to lightning strikes than others. This is a primary cause of GFCI failures. The International Association of Electrical Inspectors obtained information from the American Society of Home Inspectors about its findings in inspecting residences. This survey only covered parts of the United States, and some of the figures are staggering about the number of GFCIs that do not operate properly.

In parts of Florida, up to 58 percent of the GFCI circuit breakers were defective, and 33 percent of the receptacles. Of the states from which information was obtained, Washington state had the least number of failures. The survey covered parts of New York, Florida, Texas, California, Washington, and Illinois. IAEI, ASHI, and the National Electrical Manufacturing Association are joining forces get data from each state to give a true picture of the failures throughout the United States.

THE BOTTOM LINE FOR SAFETY
If you follow just these two steps, whether at home or at work, you can help ensure that your GFCIs function as life-protecting devices.

  1. Test them monthly as required.
  2. When a GFCI trips, reset and then trip it using either a GFCI tester or test buttons on the device. (Make sure this stops the current flow). Reset and use the circuit!

Electrical
 
Save Time And Money By Doing Your Own Basic Electric Wiring
1/1/0001 12:00 AM
Save Time & Money Doing Your Own Basic Electric Wiring Article from: Nico De Baere Hiring a professional electrician can be very expensive and is often the reason why people try doing their own basic electric wiring themselves.   I have... ......
 
A Look at Electrician Training
1/1/0001 12:00 AM
Once you've selected the school you wish to attend, gone through the application procedures and started to train you'll get a better idea of what area you'd like to specialize in as an electrician.At some point in time you may want to consider... ......
 
Seeing the Light
1/1/0001 12:00 AM
Lighting Light has illuminated the path of humanity - While Einstein was probably referring to one of his mind-blowing theories, lighting has also revolutionized the home. Before incandescent and fluorescent lighting, most activities... ......
 
What are Circuit Breakers?
1/1/0001 12:00 AM
Circuit Breakers are devices that stop the electrical current of a circuit in the event of excess or very high voltage. Circuit breakers are handy, not only because they can protect against electrical fires but also because they can be reset. When... ......
 
Top Electrician Jobs
1/1/0001 12:00 AM
In today's high speed world where information moves at the speed of light across the country, electrician jobs go unfilled for lack of qualified, talented individuals. There are entire websites and head hunting personnel firms that specialize in... ......
 
Energy-saving ideas for setting holiday lights aglow
1/1/0001 12:00 AM
(NC)-Lighting up the home for the holiday season is a great way to add warmth and a touch of holiday spirit to any home. The lighting team at Canadian Tire has put together some tips to help Canadians add a little lighting magic to their homes... ......
 
Complete Home Rehab In 10 Days
1/1/0001 12:00 AM
This report is about taking a house and restoring it to an aesthetically pleasing dwelling that has reclaimed it's functional utility. In effect, it is the anti-aging medication for bricks and mortar. This report assumes that you have... ......
 
How A Light Bulb Works and Other Interesting Tidbits
1/1/0001 12:00 AM
How A Light Bulb Works and Other Interesting Tidbits Light Bulb Science Ever wonder how a light bulb works? I mean it seems easy, you flick a switch and bam there is light! While not much more complicated than that, there is a little science... ......
 
Stop Dreaming! Magically Transform Your Garden By Night
1/1/0001 12:00 AM
(ARA) - It's cold in most areas of the country, but those of us who love our gardens can't help but dream of the spring, when we can spruce up our homes with color and life. We take pride in our gardens, spending thousands of dollars making... ......
 
An Electrician's Tools
1/1/0001 12:00 AM
There are such a wide variety of electrician tools available on the marketplace that there are entire books on the subject and even they can't cover everything. Depending on the job you are doing and the jobs you hope to be doing, there are... ......













Buyer's Choice Home Inspection 1735 Audubon Trail Lutz, FL 33549
Phone: Fax:

Radon-Information | Staff-Profiles | Contact-Us | Roof Installation | During Roof Install | Tile Maintenance | Upgrading Electrical System | Water Heater Problems | Weatherstripping | Whole House Fans | Wood Rot | Home - Maintenance | Inspection Process | Roofs | Plumbing | Electrical | Fireplace Maintenance | Fireplaces | Dishwasher Problems | Kitchen and Baths | How Electricity Works | Inspection-Tour | Question | Power Outage | Florida Wind Map - Old | Appliance Tips | Carbon Monoxide FAQ | HUD News | CPSC News | Old House WEB | Money Pit | Do It Yourself | Hurricane Information | Storm Prediction Center | Tampa Bay Weather | Link to Us | Entrapment Hazards | Wiring Sizes | Child Safety Tips | For Agents & Brokers | Plumbing Materials | Hurricane Shields | Environmental-Issues | Compare Estimates | Mold | Mfg Homes | Repair Cost Guide | Resources | Lead | Pressure Treated Wood | Plumbing Fundamentals | Lightning Protection | Service Wires | Roof-Siding-Deck-Window | Custom Home Builder News | Home Construction News | Home Building News | Residential Architect News | FVIR Water Heaters | Prepare for Thunderstorms | Perils in Florida | Seller's Checklist | Safety Checklist | Wild Life Control | After the Inspection | Home Maintenance | Senior Safety Tips | Biological Pollutants | Inspection-Guide | Home Safety Tips | Drowning Prevention | Fences FAQ | Resources Links | Tips Inspecting Roof | Styles of Roofs | Roof Slope | Inside Roof Inspection | Outside Roof Inspection | Cool Metal Roof | Site-Directory | Occupational Safety News | Household & Consumer News | Tampa Bay News | JLC Online | Mr. Fix-It Tips | Spas, Hot-Tubs | Florida Wind Map - New | Wind Map - Hillsborough | Wind Map - Pinellas | Avoiding Wind Damage | FL Bldg Code Changes | Home Interiors | Lightning | Pre-purchase Checklist | Plumbing & HVAC News | Defects Defined | Dryer Vent Safety | Well & Septic Systems | Electric Terminology | Inspector Resources | Home Clinic | How Your House Works | Home Improvement | Finding Contractors | FPE Panels | GFCI Outlets | Rewire Old Homes | Surge Protection | Pool Sanitizers | Home Construction | Trusted Broker's Blog | Door Locks Basics | Dryrot Issues | Plumbing FAQ | Moving Tips | Septic Maintenance | Septic Problems | Roofing Terms | Attic Ventilation | Roof Concerns by Type | Hiring Contractors | Polybutylene | Environment | Roof Ventilation | Other States | Florida | Garage Door Safety | Tap Water Scalds | Building Topics | Thermal Windows | Thermostats | Garage Fire Safety | History of Building Codes | Home Emergencies | Home Lighting | Preventive Maintenance | Home Security | Child Proof Home | Chimney Maintenance | Clean Water Supply | Concrete Slab Maintenance | Deck Maintenance | Health & Safety | HVAC | Homeowner Resources | Technical Resources | New Construction Inspections | 1yr Warranty Inspection | 4-Point Insurance Inspection | Other Types Services | 7-Keys to Find Inspector | Ungrounded Outlets | Simpson Strong-Ties | Construction-Terms | Home Journal | Home Improvement Watch | Discovery Technology | Real Estate News | Electrical News | Construction News | We Are Independent | Roofing Basics | Hurricane | Flood | Thunderstorm | Water Heater Ages | Indoor Air Quality | Masonry Fireplaces | Mold FAQ | On Demand Water Heaters | Overloading Electrical Circuits | Plumbing Systems | Pool Heaters | House to Code? | Automatic Fire Sprinklers | Other Inspectors | ASHI Home Inspections - FAQ | Small Home Repairs | Solar Heating | 13 SEER Systems | Other Inspectors 2 | AC Maintenance Tips | Air Filters | Pool Safety | Energy Conservation | Child Safety | Electricity Basics | Energy Star Ratings | Prevent Mildew | Radon Testing & Removal | Rain Gutters | Reading Blue Prints | Remodeling Process | Efficency Ratings | Construction & Building News | Safety Barriers | Landscape and Gardening | Coastal Construction | This Old House | Construction.com | Ask The Builder | Build Your Own Home | Building News | Design & Construction | Housing Zone | Builder - Constructor | Homeowner Resource Site | Do It Yourself Project Videos | Home Improvement Tips | Client-Login | Home-Buyer-Checklist | Download Adobe Acrobat | Tell-a-Friend | Real-Estate-News | FAQ | Real-Estate-Terms | Home | Site Map | Mortgage Calculators | Our-Service-Area | Common Defects | Inspector-Services | Inspection-vs-Appraisal | Inspector-vs-Engineer | New-Home-Inspection | Purchase-Inspection | Septic-Inspection | The Home Inspection | Listing-Inspection | Request Info | Truss-uplift | Maintaining Wells | Mold-in-the-Home | Types-of-wells | Well Inspections | Our-Technology | How-to-prepare | Investment Homes | ASHI-Membership | ASHI-Code-of-Ethics | Choosing an Inspector | HVAC-Issues | Geo-Soils Report | Roofing-Issues | Hidden-Water-Damage | Plumbing-Issues | Termites and Other Pests | Asbestos-Information | Mfg-vs-ModularHomes

Copyright © 2008 Buyer's Choice Home Inspection
Portions Copyright © 2008 a la mode, inc.
Another XSite by a la mode, inc. | Terms of UseSite Map